{"product_id":"large-area-work-light-powertube-ii-m-230v-ac-on-off-with-ip68-plug","title":"Large area work light POWERTUBE II M 230V AC on\/off with IP68 plug","description":"\u003ch2\u003eProduct overview\u003c\/h2\u003e\n\u003cp\u003eThe SONLUX POWERTUBE II M is a mobile large-area LED luminaire that delivers wide, comfortable illumination for temporary work zones. Its tube construction produces a true 360° light field, so the scene stays readable from every side. This reduces harsh shadows behind people, machinery, pallets, and barriers. It also helps keep the site organised, because fewer fixtures are needed to achieve uniform coverage.\u003c\/p\u003e\n\n\u003cp\u003eThis specific version uses a rugged toggle switch for straightforward operation. You can select \u003cstrong\u003eOff\u003c\/strong\u003e, \u003cstrong\u003e180° illumination\u003c\/strong\u003e, or \u003cstrong\u003e360° illumination\u003c\/strong\u003e. That makes it easy to focus light on a defined work face or expand to full-area lighting when the team moves around the luminaire. No external controllers are required.\u003c\/p\u003e\n\n\u003ch2\u003eThree-position switch: Off \/ 180° \/ 360°\u003c\/h2\u003e\n\u003cp\u003eTemporary lighting often needs quick decisions. Full-area mode is perfect for teams working around the lamp. Half-area mode is ideal for boundaries, corridors, and work faces where you want to limit spill and reduce glare. With the POWERTUBE II M, you can switch modes in seconds. In 180° mode, the rated luminous flux is \u003cstrong\u003e12,000 lm\u003c\/strong\u003e. In 360° mode, it is \u003cstrong\u003e24,000 lm\u003c\/strong\u003e. This flexibility supports better energy use and cleaner lighting setups.\u003c\/p\u003e\n\n\u003ch3\u003ePractical power levels for daily work\u003c\/h3\u003e\n\u003cp\u003eIn 180° mode, system power is \u003cstrong\u003e94 W\u003c\/strong\u003e. In 360° mode, it is \u003cstrong\u003e187 W\u003c\/strong\u003e. Both modes maintain a strong system efficiency of \u003cstrong\u003e128 lm\/W\u003c\/strong\u003e. That means you get a lot of usable light without overloading the circuit plan. It also helps when you run multiple units on one temporary distribution.\u003c\/p\u003e\n\n\u003ch2\u003eUniform light quality with 5000 K and CRI 80\u003c\/h2\u003e\n\u003cp\u003eThe POWERTUBE II M uses a 5000 K colour temperature for a clear, neutral “daylight” appearance. With CRI 80, colours stay consistent for safety markings, wiring identification, and tool recognition. The opal polycarbonate diffuser spreads the light evenly and reduces glare. This is valuable on wet asphalt, metal surfaces, and glossy indoor floors where reflections can cause eye fatigue.\u003c\/p\u003e\n\n\u003ch2\u003eRugged build for transport and harsh conditions\u003c\/h2\u003e\n\u003cp\u003eThe housing is aluminium and powder-coated for durability. The base plate is steel, powder-coated, and fitted with rubber feet for stability and grip. The diffuser tube is impact- and break-resistant polycarbonate, built to withstand frequent packing and repositioning. The luminaire is rated \u003cstrong\u003eIP65\u003c\/strong\u003e for protection against dust and water jets and \u003cstrong\u003eIK08\u003c\/strong\u003e for impact resistance.\u003c\/p\u003e\n\n\u003ch3\u003eDesigned for jobsite reality\u003c\/h3\u003e\n\u003cp\u003eFast relocations and tight schedules are normal in temporary lighting. This luminaire is built to be carried, mounted, and packed repeatedly. A high-temperature filament test rating of \u003cstrong\u003e850 °C\u003c\/strong\u003e supports robust material selection for demanding environments.\u003c\/p\u003e\n\n\u003ch2\u003eIP68 plug concept for wet and exposed locations\u003c\/h2\u003e\n\u003cp\u003eThis version is supplied with a Type E+F plug (CEE 7\/7) with an IP68-rated plug concept. It is a practical advantage when conditions are wet, muddy, or unpredictable. Think of rain, spray, splash zones, and puddle-prone ground. The goal is better reliability at the connection point and fewer interruptions on outdoor work.\u003c\/p\u003e\n\n\u003ch2\u003eMounting options: mast, floor, or suspension\u003c\/h2\u003e\n\u003cp\u003ePOWERTUBE II M can be used on a mast (tripod), as a floor luminaire, or suspended. The integrated holding sleeve fits a \u003cstrong\u003e30 mm stand spigot\u003c\/strong\u003e according to \u003cstrong\u003eDIN 14640\u003c\/strong\u003e, which matches common professional tripods used for large-area lighting. Suspension is useful when you need the floor clear for access routes, loading, or safe movement around equipment.\u003c\/p\u003e\n\n\u003ch3\u003eSetup tips that improve coverage\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount higher on a mast to expand the light field.\u003c\/li\u003e\n  \u003cli\u003eUse 180° mode for corridors and defined work faces.\u003c\/li\u003e\n  \u003cli\u003eUse 360° mode when teams work around the lamp.\u003c\/li\u003e\n  \u003cli\u003eRoute cables away from walkways to reduce trip risks.\u003c\/li\u003e\n  \u003cli\u003eKeep the diffuser clean for stable uniform output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical planning and inrush behaviour\u003c\/h2\u003e\n\u003cp\u003eTemporary grids and generators can be sensitive to inrush peaks. This luminaire has defined inrush behaviour: \u003cstrong\u003e100 A\u003c\/strong\u003e with a duration of \u003cstrong\u003e209 µs\u003c\/strong\u003e. For practical circuit planning, the guideline is: up to \u003cstrong\u003e3\u003c\/strong\u003e luminaires on a \u003cstrong\u003eB10A\u003c\/strong\u003e fuse, up to \u003cstrong\u003e5\u003c\/strong\u003e on \u003cstrong\u003eB16A\u003c\/strong\u003e, up to \u003cstrong\u003e5\u003c\/strong\u003e on \u003cstrong\u003eC10A\u003c\/strong\u003e, and up to \u003cstrong\u003e8\u003c\/strong\u003e on \u003cstrong\u003eC16A\u003c\/strong\u003e. Always apply local electrical regulations and consider cable length, supply quality, and site conditions.\u003c\/p\u003e\n\n\u003ch2\u003eWhat is included\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e The product includes only the lamp and a textile carrying bag. Masts (tripods) and any additional accessories are sold separately and can be selected as optional accessories.\u003c\/p\u003e\n\n\u003ch2\u003eBasic technical specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePOWERTUBE II M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e73P01001-0006\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e590 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.72 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 K\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCRI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle switch: Off \/ 180° \/ 360°\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated luminous flux\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 lm (180°) | 24,000 lm (360°)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e94 W (180°) | 187 W (360°)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128 lm\/W (180°) | 128 lm\/W (360°)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBeam angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDown 180° | 90°\/90°\/0°\/90°\u003cbr\u003eUp 180° | 90°\/90°\/0°\/90°\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGlare evaluation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRUG (4H\/8H): 28.1 | 29.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDriver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOn\/off via toggle switch\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240 V \/ 50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpact resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass II\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilament test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED rated life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50,000 h (L80\/B50)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotobiological safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 62471, Risk group 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current \/ duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A \/ 209 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLuminaires per fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB10A: 3 | B16A: 5 | C10A: 5 | C16A: 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply cable \/ plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 m, H07RN-F, 2 × 1.0 mm² \/ Type E+F (CEE 7\/7), IP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFloor use, mast (tripod), suspension\u003cbr\u003e30 mm stand spigot sleeve (DIN 14640)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTextile carrying bag\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhere this version fits best\u003c\/h2\u003e\n\u003cp\u003eIf you want the M-size POWERTUBE with the simplest switching concept and extra confidence at the connection point, this is the right choice. Use 180° mode to light a defined area without over-lighting. Switch to 360° mode when the work zone expands and teams move around the luminaire. The IP68 plug concept helps when weather and ground conditions are not ideal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNOTE: The product includes only the lamp and a textile carrying bag. Masts (tripods) and any additional accessories are sold separately and can be selected as optional accessories.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Sonlux","offers":[{"title":"Default Title","offer_id":52220980429142,"sku":"73P01001-0006","price":1297.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/5641\/8969\/files\/Apparecchio_di_illuminazione_per_grandi_aree_POWERTUBE_II_M_73P01000-0006_acceso_spento_con_spina_IP68.jpg?v=1767721350","url":"https:\/\/drava.shop\/products\/large-area-work-light-powertube-ii-m-230v-ac-on-off-with-ip68-plug","provider":"Drava Shop","version":"1.0","type":"link"}